IAM: Difference between revisions
No edit summary |
|||
Line 67: | Line 67: | ||
=== Flame System === | === Flame System === | ||
* 18 Different effects | |||
* 16 Perimeter Effects | |||
* 60' Fire Ball | |||
* Manual Control & Automatic Mode | |||
- Insane | |||
=== Laser System === | === Laser System === | ||
=== Audio Pixel === | === Audio Pixel === | ||
== l00nie-PET == | |||
=== Black Box === | |||
Testing and manual control interface rig. | |||
[[Image:ButtonRig.jpg|640]] | |||
== Calendar == | == Calendar == | ||
Saturday, July 27th Compression Fire & Art Festival | * Saturday, July 27th Compression Fire & Art Festival | ||
~August 15th Advance Team | * ~August 15th Advance Team | ||
September 5th, Wrap Up | * September 5th, Wrap Up |
Revision as of 20:25, 14 July 2013
Control Tower
_________ __ .__ \_ ___ \ ____ _____/ |________ ____ | | / \ \/ / _ \ / \ __\_ __ \/ _ \| | \ \___( <_> ) | \ | | | \( <_> ) |__ \______ /\____/|___| /__| |__| \____/|____/ \/ \/ ___________ \__ ___/_____ _ __ ___________ | | / _ \ \/ \/ // __ \_ __ \ | |( <_> ) /\ ___/| | \/ |____| \____/ \/\_/ \___ >__| \/
l00nie-crew hacker page Six26 (talk) 21:09, 10 July 2013 (UTC)
http://internationalartsmegacrew.com/controltower/
- Lasers
- One big one with sweeper
- ~4 inner lasers
- Fire
- 8 Points w/2 Flame effects
- Giant fucking! one on top
- Lighting
- RGB LED Spots ~16-24
- Doppler Radar
- Audio Pixel
Crowd Sensors
More DopplerCan
- 8 Doppler Radar Can
- Analog signal output
- Digital signal processor
- Interactions quantified in 8 sectors
Doppler sensor guts and aluminum housing. Can mount housings directly to bamboo structure or rivet with brackets.
The data has a baseline voltage of about 0.16 and a peaks of about 0.6 volts. Maximum output range is presently 0 to 3.5 volts DC and can be scaled up or down.
The baseline of 0.16vdc represents the "noise floor" of the sensor. This is the voltage output with no observable motion out to about 10 meters away, assuming an object the size of 1 person.
Sensor output data, shows a person about 4 meters from sensor taking one step forward, one back, then waiting about 10 seconds and repeated three times.
The dopplers are designed to output a smoothed wave which indicates a combined "motion" and "size/distance" value. A small object, moving any direction, close to sensor, will read similarly to a larger object moving faster, proportionately further away.
The Doppler system should be able to recognize certain type of synchronized group motions. For example, if 8 people start walking towards the tower pillars (those with Doppler attached) then the signal on all 8 dopplers will start growing in amplitude. As soon as they stop walking, no matter where, signal outputs return to baseline.
As far as power goes, the sensors need 5 volt DC and ground, current needs are about 40ma each. As far as signal output goes, the sensors output either a single-ended or differential voltage drive output, to be received by A/D host.
8 of these sensors in total are planned, possibly 4 pointing in and 4 pointing out.
Flame System
- 18 Different effects
- 16 Perimeter Effects
- 60' Fire Ball
- Manual Control & Automatic Mode
- Insane
Laser System
Audio Pixel
l00nie-PET
Black Box
Testing and manual control interface rig.
Calendar
- Saturday, July 27th Compression Fire & Art Festival
- ~August 15th Advance Team
- September 5th, Wrap Up