what is value of c33? 50 pF or 1 nF ? | what is value of c33? 50 pF or 1 nF ? | ||
determines high-cut frequency either 160 Hz (1 nF) or 3200 Hz (50 pF) | |||
Op amps ... | Op amps ... | ||
OPA2111 - what gain? | OPA2111 - what gain? expecting ~ 100 ? | ||
what values for R27, R23, R24 ? | what values for R27, R23, R24 ? | ||
(also R28, R25, R26) | (also R28, R25, R26) | ||
Line 9: | Line 11: | ||
R23, R24 -> 100K ohms | R23, R24 -> 100K ohms | ||
cf instrumentation amp | cf instrumentation amp (figure 9 of http://www.ti.com/lit/ds/symlink/opa2111.pdf) | ||
1 + (R23 + R24) / R27 ... | |||
so 1 + (200 K / 2 K) = 101 | |||
2nd Stage AD8422 Instrumentation amp with gain resistor | 2nd Stage AD8422 Instrumentation amp with gain resistor |
Revision as of 23:12, 14 December 2016
what is value of c33? 50 pF or 1 nF ? determines high-cut frequency either 160 Hz (1 nF) or 3200 Hz (50 pF)
Op amps ... OPA2111 - what gain? expecting ~ 100 ?
what values for R27, R23, R24 ? (also R28, R25, R26)
R27 should be 2K ohms R23, R24 -> 100K ohms
cf instrumentation amp (figure 9 of http://www.ti.com/lit/ds/symlink/opa2111.pdf) 1 + (R23 + R24) / R27 ... so 1 + (200 K / 2 K) = 101
2nd Stage AD8422 Instrumentation amp with gain resistor 2(10 kΩ + RREF)/(20 kΩ + RREF) http://www.analog.com/media/en/technical-documentation/data-sheets/AD8422.pdf In figure 56, you will see that an op amp is used to input to the VREF pin.
3rd stage Low-cut (aka high-pass ) filter and DC offset to 3rd Stage OP2177ARMZ ( IC1B Ch1 and IC1A Ch2 )
4th Stage IC3D>IC3C Ch1, and IC3A>IC3B, Potentially considered a two-pole high-cut(aka low-pass)